On a True reach-in, the same code can mean different things depending on which brand of controller is fitted. Here are the display codes from True's control guide and Traulsen's owner's manuals, and what to check while the product is still cold.

NYC Commercial Kitchen Repair5 min read

On almost every True and Traulsen controller, HI means the cabinet is too warm and LO means it is too cold. Codes that name a probe or sensor (E1, P1, CAB Snr and similar) mean a temperature sensor has failed. Check your product temperature with a thermometer first. Then find your controller below. On True units, E1 does not mean the same thing on every controller brand.

True sources its controls from several makers. Its Commercial Refrigeration General Control Guide (TEC_TM_001, Rev. C, 2025) gives a separate code list for each: Carel, Danfoss, Dixell and LAE. The Traulsen codes come from two Traulsen owner's manuals: the TS Series prep-table manual (form TR35921) for the INTELA-TRAUL control, and the R & A Series manual (form TR35743) for units built after April 1, 2019.

True: codes by controller brand

Carel

  • HI: high temperature alarm. LO: low temperature alarm.
  • dOr: door open alarm.
  • E0 / E1 / E2: probe 1, probe 2 and probe 3 error. On Carel, E1 is the second probe.
  • dF: defrost in progress. Ed: defrost ended by maximum defrost time.

Danfoss ERC

  • Hi / Lo: high or low temperature alarm.
  • dor: door open alarm.
  • Con: condenser alarm.
  • LEA: refrigerant leakage alarm.
  • E01 to E04: sensor S1 to S4 failure.
  • EoC: communication error between the control and the display.
  • non: display sensor not configured correctly. SYn: connected display not compatible with the control.
  • uHi: high voltage alarm. uLi or uLo: low voltage alarm.
  • deF: defrost.

Danfoss ETC

  • Hi / Lo: high or low temperature alarm.
  • E1 / E2: sensor 1 or sensor 2 defect.
  • E4: compressor fault. E5: heater fault. E6: pot fault.
  • E13: communication error.
  • Ulo / UHi: low or high supply voltage.

Dixell (XR / XW)

  • HA / LA: maximum or minimum temperature alarm.
  • P1: thermostat probe failure. P2: evaporator probe failure. P3: auxiliary probe failure.
  • EE: data or memory failure.
  • dA: door switch alarm.
  • EAL / BAL: external alarm or serious external alarm.
  • PAL: pressure switch alarm.
  • True notes that pressing any button silences a Dixell alarm.

LAE

  • hi / Lo: high or low temperature alarm.
  • do: door open alarm.
  • E1 / E2 / E3: probe T1, T2 or T3 failure. On LAE, E1 is the first probe.
  • dEF: defrost in progress. oFF: controller in stand-by. Loc: keypad locked.
  • t1, t2, t3, thi, tLo: probe readings and recorded maximum and minimum temperatures. These are information displays, not faults.

Traulsen: INTELA-TRAUL control (TS Series manual)

  • HI CAb: cabinet air rose above the preset limit. Press alarm cancel to silence it. If the temperature doesn't recover within 5 minutes, the alarm returns with "Call Service". Traulsen lists doors left open, a large load of hot product, a dirty condenser coil, compressor failure or refrigeration problems as causes.
  • Lo Cab: cabinet air fell below the limit. Listed causes are no product in the unit, failed sensors, or a stuck evaporator relay.
  • ELE LOS: the unit has power again after an outage. Press alarm cancel to clear it.
  • CLean FiLter: discharge temperature exceeded 140°F. If it passes 160°F, the compressor and condenser fan switch off until it falls below 140°F.
  • CAB Snr / COL Snr / DIS Snr: the cabinet, coil or discharge sensor has failed.

Traulsen: R & A Series built after April 1, 2019

On this control, alarms live in the Alarms submenu (SubMenu 4/5). They are: PowerFailAlarm, TempCabAlarm (cabinet temperature), TempEvapAlarm (evaporator), TempLiqLineAlarm (liquid line), LiqLineSDAlarm (liquid line shutdown) and EvapSDAlarm (evaporator shutdown). After a power failure, the same submenu shows TempCabAtPowerUp, the temperature when power came back, which Traulsen calls the warmest point of the outage. It also shows how long the power was down. Clear the power-fail alarm by setting PowerFailAlarm from "Alarm" back to "Normal".

What's safe to try before calling

These checks come from True's pre-diagnosis checks and Traulsen's troubleshooting tables:

  1. Check the product, not just the display. True's guide starts by asking whether the product is at the correct temperature. Use a probe thermometer. If food has been out of safe range, follow your food-safety plan.
  2. Close and check the doors. Make sure doors and drawers close and seal fully. Look for torn gaskets, overstocking and a unit that isn't level. Door alarms (dOr, dor, do, dA) point here, and Traulsen lists doors left open as a cause of the HI CAb alarm.
  3. Clear the airflow. Keep product away from the walls and the evaporator fan, and keep the area around the condenser clear. On prep tables, keep every pan seated flat in its opening, and don't double-pan.
  4. Look at the condenser. A dirty condenser coil is on both manufacturers' cause lists for high temperatures. Clean it per your installation manual with the power off, or have it done during service.
  5. After a power outage, read the power-fail data (Traulsen R & A) or note how long the power was off, then clear the alarm.
  6. Silence the alarm, don't ignore it. Silencing stops the noise. It doesn't fix a HI or LO condition.

When to call a technician

Call right away if:

  • Any probe or sensor code appears (E0 to E3, E01 to E04, P1 to P3, CAB/COL/DIS Snr).
  • A HI alarm doesn't recover after doors are closed and airflow is clear, or the display shows "Call Service".
  • You see LEA (refrigerant leak), Con, PAL, E4 (compressor fault), or a Traulsen liquid line or evaporator shutdown alarm.
  • You see voltage alarms (uHi, uLo, Ulo, UHi) or EE / E13 / EoC.

Protect your product and your inspection

Our EPA-certified technicians repair True, Traulsen and other reach-ins, prep tables and walk-ins across Manhattan and Brooklyn, with 24/7 emergency service. Pricing is confirmed before work starts, and every refrigeration repair comes with health-code documentation. Have the model, serial number and display code ready when you book.

Request service, or see our reach-in and prep table repair and walk-in cooler and freezer repair pages.

Need Help With This?

Our licensed team is ready to help. Explore our services or request a technician.

Related Articles