Manitowoc Indigo and Indigo NXT Error Codes: What E01 to E34 Mean
Manitowoc Indigo ice machines log faults as E-codes. Here is what each code means according to Manitowoc's technician's handbook, how the NXT handles long freeze and long harvest faults, and the restart Manitowoc tells owners to try first.
The two service faults Manitowoc's owner manual tells you about are E01 (long freeze cycle) and E02 (long harvest cycle). Many of the other codes are only recorded in the event log and don't sound an alert. Manitowoc's first step for owners is a simple restart: press the power button off, then on. If the machine stops again, call for service.
The code meanings below come from Manitowoc's Indigo Series Technician's Handbook (Part No. 000014794, 5/17). The Indigo NXT details come from the Indigo NXT Installation, Operation and Maintenance Manual (Part No. 000014141 Rev 07). The NXT manual names Service Faults E01 and E02. The full E-code list here is the Indigo handbook's, so confirm other codes against the handbook for your exact NXT model.
How Indigo NXT stops on a fault
Per the NXT manual:
- Long freeze: if a freeze reaches 35 minutes, the board forces a harvest. After 6 consecutive 35-minute freezes, the machine stops.
- Long harvest: if a harvest reaches 7 minutes, the board runs a water thaw cycle and goes back to freeze. After 3 consecutive long harvests, the machine stops.
- Safe mode: if the ice thickness probe or water level probe fails, the machine can keep running for up to 72 hours from its own cycle history. It shows an alert while it does. After 72 hours it goes to standby and turns off.
The older Indigo handbook defines E01 differently: 6 consecutive 60-minute freeze cycles.
Manitowoc Indigo event codes
To view them, open the Service menu and go to Event Log, then View ELog.
- E01 Long Freeze. Freeze cycles ran past the limit and the machine shut down. Call if it repeats after the restart below.
- E02 Long Harvest. Harvests ran past the limit. Call if it repeats after the restart.
- E03 Power Loss. Power to the machine was interrupted. This is logged only, with no alert.
- E04 High Condenser Temp / Water Condenser Fault. Liquid line temperature was too high on a self-contained air-cooled or water-cooled machine. You can check that nothing is blocking airflow around an air-cooled machine. Call if it repeats.
- E05 HPC Fault. The high-pressure cutout opened 3 times in a 4-hour period. Call.
- E07 Starving TXV / low on charge, E08 TXV Fault, E09 and E10 Flooding Evaporator, E11 Refrigeration Fault. These are refrigeration-system faults. On G boards from revision 4.017, several are logged only, with no alert. Call. Refrigerant work requires an EPA-certified technician.
- E12 Curtain Fault. The machine is set to make ice but has stayed in bin-full for more than 24 hours (12 hours on E boards), with the curtain switch open or the curtain off. You can check that the water curtain is installed and swings freely.
- E15 Low Liquid Line Temperature. Liquid line was below 60°F for more than 1 continuous minute during freeze. Call.
- E16 Remote Condenser Fault (ICVD condensing-unit models only). Liquid line was below 40°F or above 140°F for more than 1 continuous minute during freeze. Call.
- E19 Ice Thickness Probe Fault. The probe signal is out of range, for example because the probe is unplugged or has failed. Call.
- E20 Water System Fault. The water level probes or evaporator outlet temperature gave an unexpected reading during the cycle. Make sure the water supply valve is open, then call if it repeats.
- E21 to E24 T1 to T4 Sensor faults. A temperature sensor read outside its valid range. Call.
- E25 to E27 Bin Level Probe faults (low, medium, high sensor). Call.
- E28 AuCS. An AuCS clean was selected but no AuCS board was detected. Logged only.
- E29 USB Comm / E30 USB Download. No USB drive is in the port, or the drive is defective. Logged only.
- E31 Safe Mode. The machine is running on stored cycle history because a water level or ice thickness probe failed. Logged only, but production is affected. Call.
- E32 RS485 Comm. A device plugged into the RS485 port isn't communicating. Logged only.
- E33 Keyboard. The keyboard is unplugged or faulty. Logged only.
- E34 Display Fault.
E06, E13, E14, E17 and E18 are listed as spare (unused).
What's safe to try before calling
These steps come from the NXT manual's "Before Calling for Service" checklist:
- Restart the machine. Press the power button. The display reads "Off". Press it again and the display reads "Making Ice". If a service fault stopped the machine, it restarts after a short delay. Let it run. If it stops again, the fault has repeated, so call for service. If it keeps running, the condition has cleared itself.
- Check the water curtain. It must be installed and swinging freely. A curtain that is off or stuck open keeps the machine from running.
- Open the water supply. Make sure the incoming water service valve is on.
- Check the space around the machine. Manitowoc's checklist lists a dirty condenser coil as a cause of high-pressure cutout trips, and hot air entering the condenser as a cause of low ice production. The air around the head section must be at least 35°F (2°C).
- Check the power. If the display is dark, check that the machine is switched on. Leave fuses and wiring to a technician.
Descaling, sanitizing and condenser cleaning are in Manitowoc's maintenance section. They involve chemicals and removing panels, so schedule them rather than doing them mid-service.
When to call a technician
Call if:
- E01 or E02 comes back after the restart.
- Any refrigeration code appears (E04, E05, E07 to E11, E15, E16).
- The machine is in safe mode (E31). NXT models stop after 72 hours.
- E19 to E27 show a sensor or probe fault.
- The display is blank and the machine has power.
Get your Manitowoc back to making ice
Our EPA-certified technicians repair Manitowoc and other commercial ice machines across Manhattan and Brooklyn, with 24/7 emergency service. Pricing is confirmed before any work begins, and refrigeration repairs come with health-code documentation. Have the model number and the event code from the log ready when you book.
Request service or see our commercial ice machine repair page.
Need Help With This?
Our licensed team is ready to help. Explore our services or request a technician.
Related Articles
Hoshizaki Ice Machine Beeping? KM Series Alarm Codes Explained
A Hoshizaki KM cuber that beeps and stops is telling you which safety tripped. Here is what 1, 2, 3, 5, 6 and 7 beeps mean according to Hoshizaki's own service manuals, and what you can safely check.
Scotsman Prodigy and Prodigy Plus Ice Machine Codes Explained
The code display on a Scotsman Prodigy cuber shows letters for normal cycles and numbers for faults. Here is what each code means according to Scotsman's technical service manual, and the reset Scotsman documents.
True and Traulsen Refrigerator Error Codes: What the Display Means
On a True reach-in, the same code can mean different things depending on which brand of controller is fitted. Here are the display codes from True's control guide and Traulsen's owner's manuals, and what to check while the product is still cold.